NEC 5 Wok User Manual


  Open as PDF
of 1614
 
E911 Compatibility
330 Features Aspire Software Manual
21-02-01 : Trunk Group Routing for Extensions
Assign the routes set in Program 14-06 to extensions. This program and Program 14-06 are
the minimum required if E911 must seize a line to dial.
Aspire S Trunk Groups: 1-8
Aspire Trunk Groups: 1-100
81-01-14 : COIU Initial Data Setup - Hookash 1
81-01-15 : COIU Initial Data Setup - Hookash 2
Program the length of time the system should wait before disconnecting a call in an Emer-
gency Call forced trunk disconnect situation. The item to be programmed depends on the
entry in 14-02-04.
Related Features
Automatic Route Selection
Refer to the ARS feature for more information on setting up Selection Numbers, Dial Treat-
ments, Call Route Options and Work Periods.
Central Ofce Calls, Placing
If trunk access codes are not required in programming (21-01-12) for E911, if a user dials the
trunk access code prior to 911, the call will still go through.
Networking / VoIP
Networked IP phones can be programmed to follow ARS COS Matching in order for 911 calls
to seize a local line to call the site’s local authorities (and not the networked site’s).
T1 Trunking (with ANI/DNIS Compatibility)
With PRI trunks, set up the system so the caller’s extension number is sent to the 911 center.
Operation
To place an emergency 911 call:
When Dial 911 Routing Without Trunk Access is enabled . . .
1. Go to any phone.
2. Lift handset or press idle CALL key.
3. Dial 911.
When Dial 911 Routing Without Trunk Access is disabled . . .
1. Go to any phone.
2. Lift handset or press idle CALL key.
3. Dial a trunk access code (e.g., 9) or press a line key.
4. Dial 911.
To turn off the E911 Alarm at your telephone:
1. Lift handset or press idle CALL key.
2. Dial 886
The alarm goes off.
OR (if you have a display telephone)
1. Press CLEAR once to turn off the alarm.