Program 15 : Extension, Basic Setup
15-03 : Single Line Telephone Basic Data Setup
Aspire Software Manual Programming 907
15-03 : Single Line Telephone Basic Data Setup
Description
Use Program 15-03 : Single Line Telephone Basic Data Setup to set up various single line tele-
phone options.
Input Data
Level:
Aspire S Aspire M/L/XL
IN
Available. Available.
Item 10 available.
Item 11 available with software 2.63+.
Item 13 available with software 2.63+.
Item 14 and 15 added with software 4.0E+,
however, they are not used in the U.S.
Item 10 available with software 1.11+.
Item 11 available with software 2.63+.
Item 13 available with software 2.63+.
Item 14 and 15 added with software 4.0E+,
however, they are not used in the U.S.
Extension Number Max. 8 digits
Item
No.
Item Input Data Default
Related
Program
01 SLT Signaling Type
Use this option to tell the system the type of dial-
ing the connected telephone uses.
For each Aspire Mail extension, this option must
be set to “0”.
In order for the Aspire Wireless phones to func-
tion correctly, this must be set to ’0’ (dial pulse).
If this option is set for DTMF, after an outside call
is placed, the system will not dial any additional
digits.
This program change is automatically performed
when the Aspire Wireless phone is registered
when using system software 1.13+. When upgrad-
ing software from prior versions, the previous
default of ’1’ will be saved from the prior data-
base so this option must be changed manually.
0 = DP
1 = DTMF
1
02 Loop current
- Not Used in U.S. -
0 = 20mA
1 = 35mA
0