NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Program 24 : Hold/Transfer Setup
24-02 : System Options for Transfer
1102 Programming Aspire Software Manual
Conditions
None
Feature Cross Reference
Transfer
07 Forced Release for Trunk-to-Trunk Transfer
This timer will start when a trunk begins talking with
another trunk (for example: trunk-to-trunk transfer, out-
going from trunk, Tandem Trunking).
With software 4.0E+, when this timer expires, a warning
tone is heard. If Program 24-02-10 is set, the conversa-
tion disconnects after that timer expires. This timer is set
again when the external digit timer expires. One of the
trunks used must be an analog trunk (or leased line)
0-64800 (Seconds) 1800 24-02-10
08 Delayed transfer timer for all Department Groups 0-64800 (Seconds) 10 11-11-28
11-11-29
15-07-01,
Key 59
09 ISDN Transfer Resend Timer
Determine how long the system should resend a Facility
Message to the currently active PRI trunk when the 2
B-Channel Transfer feature is used. The system will
resend the Facility timer based on this timer. If there is no
response after the 3rd resend, the system considers the
transfer as failed and stops resending.
1-30 seconds 10
10 Trunk-to-Trunk Transfer Disconnect Timer
Determine how long a conversation will continue once
the timer in Program 24-02-07 expires. If this option is
set to "0", the conversation will be disconnected immedi-
ately. This program has no affect if Program 24-02-07 is
set to "0". One of the trunks used must be an analog trunk
(or leased line).
0 - 64800 seconds No
Setting
11 No Answer Timer for Step Transfer
Dene the length of time the system will wait before Step
Transferring a no-answer call to the next destination.
0 - 64800 seconds 10 14-01-26
24-04-01
12 No Answer Timer for Automatic Trunk-to-Trunk
Transfer
Dene the length of time the system will wait before
Automatic Trunk-to-Trunk Transfer occurs for a
no-answer call.
0 - 64800 seconds 0 14-01-26
24-04-01