NEC 5 Wok User Manual


  Open as PDF
of 1614
 
T1 Trunking (with ANI/DNIS Compatibility)
Aspire Software Manual Features 537
T1 Trunking (with ANI/DNIS Compatibility)
Description
The T1/PRI Interface PCB gives the system T1 trunking capability. This PCB uses a single univer-
sal slot and provides up to 24 trunk circuits. In additional to providing digital-quality trunking, the
T1/PRI Interface PCB allows you to have maximum trunking capability with fewer PCBs. This in
turn makes more universal slots available for other functions.
You can program each T1/PRI PCB for any combination of the following trunks:
CO loop start
CO ground start
Direct Inward Dialing
Tie lines
1
The T1/PRI Interface PCB uses the rst block of 24 consecutive trunks. For example, if you have
an 8COIU PCB installed for trunks 1-8, the T1/PRI Interface PCB will automatically use trunks 9-
32. If you have 8COIU PCBs installed for trunks 1-8 and 17-24, the T1/PRI PCB will use trunks
25-48. The T1/PRI Interface cannot use trunks 9-16 (even if available) since they are not part of a
consecutive block of 24 trunks. Each T1/PRI PCB requires that 24 consecutive ports be available in
the system even if not all the ports will be used otherwise the PCB will not function.
ANI/DNIS Compatibility
The system is compatible with telco’s T1 Automatic Number Identication (ANI) and Dialed
Number Information Service (DNIS) services. This is only for T1 - not for PRI at this time). A
compliment to Caller ID service, ANI/DNIS Compatibility provides:
Selectable Receive Format
You can set up the system for compatibility with any combination of ANI, DNIS and Dialed
Number (Address) data provided by the telco.
Flexible Routing
Based on the data received, the system can route the incoming ANI/DNIS call to:
- An extension
- An ACD or Voice Mail master extension number
- The VRS and play a VRS message to the caller.
- A Department Group pilot number
- A trunk Ring Group
Route According to DID Translation Table or Abbreviated Dial Bins
Calls can be routed based on either the number of digits dened in Program 22-09-01 (digits
1-8) or by digits entered in Abbreviated Dial bins in Program 13-04-01.
ANI/DNIS Data Displayed as Caller ID Data
Data Error and Unanswered Call Handling
If a call can’t be completed, send it to a predetermined Ring Group or play supervisory tones
to the caller.
Aspire S Aspire M/L/XL
Not Available. Available
ANI/DNIS Compatibility is available.
This feature requires the Basic NTCPU (P/N 0891002)
with the PAL upgrade or the Enhanced NTCPU (P/N
0891038) unless using software 4.0E or higher.
1. Two-wire (four-lead) type 1 tie lines (FIC TL11M) only.