ISDN Compatibility
Aspire Software Manual Features 375
BRI and DID Callers with Non-Matching SPID Numbers
This feature allows you to determine whether the system will check the called party number with
the SETUP message and the SPID setup. Depending on the system programming, this can allow
DID calls to be received on BRI trunks and direct them according to the DID Translation Table
(Program 22-11-03).
Ringback Tone to Telco Now Possible with BRI Trunks
An option is available using Program 10-03-17 which can be used to determine whether or not the
system sends ringback tone to the telco.
Conditions
Refer to the ISDN-BRI Manual (P/N TBD) and ISDN-PRI Manual (P/N 0893212) for the specics.
Default Setting
None
Programming
Refer to the ISDN-BRI Manual (P/N TBD) and ISDN-PRI Manual (P/N 0893212) for the specics.
10-03-01 : PCB Setup - ISDN Line Mode
Setup and conrm the Basic Conguration data for each PCB. This program selects the ISDN
Line Mode: 0=Not set, 1=T-Bus, 2=S-Bus, 3=Network Mode (Leased Line), 4=Network
Mode (Interconnected Line), 5=Network Mode (Interconnected Line, Fixed Layer 1=NT),
6=S-Point (Leased Line). The option selected here determines the clock source for a net-
worked system. With option 3, telco sends the clock to the master and slave systems. With
option 4, the master system sends the clock to telco which then sends the clock to the slave
system (with no telco, the master system sends the clock directly to the slave system). With
option 5, the master and slave systems both send the clock to telco.
10-03-02 : PCB Setup - Logical Port Number
Setup and conrm the Basic Conguration data for each PCB. This program displays the start
port number of a PRI line. Thirty logic ports are automatically assigned to a PRI line (T-Bus =
1-200, S-Bus = 1-256).
10-03-03 : PCB Setup - CRC Multi-Frame (CRC4)
Setup and conrm the Basic Conguration data for each PCB. This program determines
whether or not the CRC Multi-Frame (CRC4) is used (0=off, 1=on).
10-03-04 : PCB Setup - Layer 3 Timer Type
Setup and conrm the Basic Conguration data for each PCB. This program selects the Layer
3 timer type (1-5). Each timer value of Layer 3 is set up for each type in Program 81-06 (T-
Bus) and Program 82-06 (S-Bus).
10-03-05 : PCB Setup - CLIP Information
Based on this setting, the system will include a “Presentation Allowed” (1) or “Presentation
Restricted” (0) in the Setup message to allow or deny the Calling Party Number. Program 15-
01-04 must also be set to a ‘1’ if this option is enabled.
10-03-06 : PCB Setup - Length of Cable
Setup and conrm the Basic Conguration data for each PCB. Select the length of cable to be
used (0=0-40m, 1=40 81m, 2=81-122m, 3=122-162m, 4=162-200m).
10-03-07 : PCB Setup - S-Point DID Digits
Setup and conrm the Basic Conguration data for each PCB. This program selects number
of DID digits to be received (0-4).