NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Program 34 : Tie Line Setup
34-01 : E&M Tie Line Basic Setup
Aspire Software Manual Programming 1199
Program 34 : Tie Line Setup
34-01 : E&M Tie Line Basic Setup
Description
Use Program 34-01 : E&M Tie Line Basic Setup to denes the basic settings for each E&M tie
line.
Input Data
Conditions
None
Feature Cross Reference
Tie Lines
Level:
Aspire S Aspire M/L/XL
IN Available. Available.
Trunk Port Number Aspire S: 1-8
Aspire: 001-200
Item
No.
Item Input Data Default
Related
Program
01 DID/E&M Start Signaling
Set the start signaling mode for DID and tie trunks. DID and tie
trunks can use either immediate start or wink start signaling.
0 = 2
nd
dial tone
1 = Wink
2 = Immediate
3 = Delay
1 22-02
02 DID/E&M Incoming
Signaling Type
For DID and tie trunks, use this option to set the trunk’s signal-
ing type (Dial Pulse or DTMF)
0 = Dial Pulse
1 = PB (DTMF)
0 10-09
03 E&M Dial-In Mode
Determine if the incoming tie line call should be directed as an
intercom call or if it should follow the DID Translation Table in
Program 22-11.
0 = Specify
Extension number
1 = Use
conversion table
0 22-11
04 E&M Line Dial Tone
Enter 1 if the tie line should send dial tone to the calling system
once the call is set up. Enter 0 if the tie line should not send dial
tone.
0 = Disable
1 = Enable
1
05 System Toll Restriction
Enable (1) or disable (0) the ability for tie line calls to follow
the system toll restriction entries in Programs 21-05-01 through
21-05-13. If disabled, tie line toll restriction will be determined
by 21-05-13.
0 = Disable
1 = Enable
0 21-05-13
34-08-01