NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Warning Tone For Long Conversation
Aspire Software Manual Features 703
Programming
14-01-17 : Basic Trunk Data Setup - Trunk to Trunk Warning Tone for Long Conversation
Alarm
Determine whether DISA callers should hear the Warning Tone for Long Conversations
(0=disabled, 1=enabled).
20-06-01 : Class of Service for Extensions
Assign a Class Of Service (1-15) to an extension.
20-13-01 : Class of Service Options (Supplementary Service) - Long Conversation Alarm
In an extension’s Class of Service, enable (1) or disable (0) Warning Tone for Long
Conversation.
20-21-01 : System Options for Long Conversation - Long Conversation Alarm 1
After a user places a trunk call, the system sends the rst warning tone to their extension after
this interval (0-64800 seconds).
20-21-02 : System Options for Long Conversation - Long Conversation Alarm 2
After hearing the rst warning tone, the system sends additional warning tones after this inter-
val (0- 64800 seconds). The warning tones continue, spaced by this interval, until the user
hangs up.
21-01-01 : System Options for Outgoing Calls - Trunk Interdigit Time (External)
Determine the length of time the system should wait before starting the Warning Tone Timer.
25-07-07 : System Timers for VRS/DISA - DISA Conversation Warning Tone Time
Determine the length of time the system should wait before the Warning Tone is heard by
DISA callers (0-64800 seconds). If an outside call is transferred or forwarded off-premise
using an outside trunk, this timer starts immediately. This will occur if either trunk involved in
the call is programmed for the Warning Tone (Program 14-01-17).
25-07-08 : System Timers for VRS/DISA - DISA Long Conversation Disconnect
Determine how long after the Warning Tone is heard the system will wait before disconnect-
ing DISA calls - unless the Continue code is entered (Program 25-13-02).
25-13-02 : System Option for DISA - Continue Code for DISA Trunk-to-Trunk
With software through 2.68, enter a single digit Continue Code for the DISA call to use to
immediately disconnect or continue their outside call (0-9, * or # are accepted entries). With
software 4.0E+, use Program 20-28-01.
25-13-03 : System Option for DISA - Disconnect Code for DISA Trunk-to-Trunk
With software through 2.68, enter a single digit Disconnect for the DISA call to use to imme-
diately disconnect or continue their outside call (0-9, * or # are accepted entries). With soft-
ware 4.0E+, use Program 20-28-02.