NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Door Box
Aspire Software Manual Features 323
Door Box
Description
The Door Box is a self-contained Intercom unit typically used to monitor an entrance door. A visi-
tor at the door can press the Door Box call button (like a door bell). The Door Box then sends chime
tones to all extensions programmed to receive chimes. To answer the chime, the called extension
user just lifts the handset. This lets the extension user talk to the visitor at the Door Box. The Door
Box is convenient to have at a delivery entrance, for example. It is not necessary to have company
personnel monitor the delivery entrance; they just answer the Door Box chimes instead. Any num-
ber of system extensions can receive Door Box chime tones.
Each Door Box has a pair of normally open relay contacts that can connect to an electric door
strike. Use these contacts to remotely control the entrance door. After answering the Door Box
chimes, a keyset user can press FLASH to activate the Door Box contacts. This in turn releases the
electric strike on the entrance door. The device connected to the Door Box contacts cannot exceed
the contact ratings shown in the table below:
The system can have up to eight Door Boxes.
Conditions
(A.) Each channel in the 2PGDAD has a jumper which must be set for Door Box operation. Refer
to the system hardware manual for additional details.
(B.) There is no off-hook ringing for Door Boxes. If an extension user is on the phone, the CALL2
key will ash, but no ringing will be heard.
Default Setting
Disabled.
Programming
10-03-01 : PCB Setup - Channel 1 Terminal Type
10-03-06 : PCB Setup - Channel 2 Terminal Type
The terminal type should be assigned type “8” for Door Box usage.
10-05-01 : General Purpose Relay Setup
Dene which Relay circuits (5-8) on a 2PGDAD Adapter are used for General Purpose Relay.
Refer to Program 10-21-01 for the NTCPU relay.
Aspire S Aspire M/L/XL
Available - 4 Door Boxes and 6 Chime Tones. Available - 8 Door Boxes and 6 Chime Tones.
Door Box Specications
Contact Conguration Normally Open
Maximum Load 60mA@30 VDC
10mA @90 VDC
Maximum Initial Contact Resistance 50mOhms