NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Program 30 : DSS/DLS Console Setup
30-03 : DSS Console Key Assignment
Aspire Software Manual Programming 1159
30-03 : DSS Console Key Assignment
Description
Use Program 30-03 : DSS Console Key Assignments to customize the key assignments for
110-Button DSS Consoles. The DSS Console keys can be programmed using any of the function
codes listed below. In addition, the key (when dened as a DSS/One-Touch key [code 01] can have
any function up to four digits long (e.g., extension number or Service Code). The function informa-
tion (such as extension number or Service Code) would then be entered as the additional data.
To prevent lamping problems when reassigning DSS Console keys, it is recommended that you
clear an extension's programmed key before reassigning it (Enter key to be cleared + 00 or *00 [If
using Web or PC Programming, delete the key assignments and upload the change to the system
before proceeding]). Without clearing an extension's key rst, your DSS Console may not show the
correct lamping, although the DSS function will work correctly.
If you are programming the system from the extension to which the DSS Console is connected,
either by phone or using the Web or PC Program, you may need to unplug the DSS and plug it back
in to reset the console's lamping.
Input Data
Index 1
Index 2
Level:
Aspire S Aspire M/L/XL
SA
Available. Available.
Item 88 requires software 4.93+. Item 88 requires software 4.93+.
DSS Console Number Aspire S: 1-4
Aspire: 01-32
Item No. Key Number Function Number Additional Data
01 001-200 0-99 (General functional level)
* 00-* 99 (Appearance functional level)
Refer to functional number list