Loop Keys
390 Features Aspire Software Manual
Related Features
Automatic Route Selection (ARS) / Central Ofce Calls, Answering / Central Ofce
Calls, Placing
Program incoming and outgoing access and routing options.
Off Hook Signaling
If enabled, a user hears Call Waiting beeps if additional calls are waiting behind a loop key.
Programmable Function Keys
If you have a line and loop key for the same trunk, the line key has precedence. An incoming
call rings the line key, not the loop key. When you press the loop key for an outgoing call, the
line key lights.
Trunk Group/Loop Key (*02), Virtual Extension (*03), and Loop Key (*05) codes can not be pro-
grammed on a DSS Console as the system does not allow entry of the additional data required.
Ring Groups
Trunks ring telephones according to their Ring Group assignments (Programs 22-04 and 22-05).
Direct Inward Dialing (DID) / Direct Inward Line (DIL) / Direct Inward System Access
(DISA) / Tie Lines
Transferred DID, DIL, DISA and tie line calls do not require ring group programming.
Operation
To place a call on a loop key:
1. Press outgoing or both ways loop key.
You hear dial tone and the key lights green.
2. Dial number.
To answer a call on a loop key:
Listen for ringing a look for a ashing loop key.
1. Press loop key.
The key lights green and you connect to the call.
If there are additional calls waiting to be answered, your display shows:
WAITING - LOOP KEY
To program a loop key:
1. Press the SPK key.
2. Dial 852.
3. Press the key you want to program as a loop key.
4. Dial *05.
5. Dial the loop key type:
0 = Incoming only
1 = Outgoing only
2 = Both ways (incoming and outgoing)
6. Dial the loop key routing option for incoming, outgoing, or incoming and outgoing calls:
000 = Trunk Group Routing or ARS (if installed)
001-200 = Trunk Groups
If you selected option 2 in step 5 above, enter the incoming Trunk Group followed by
the outgoing Trunk Group.