DES-7200 Configuration Guide Chapter 4 802.1x Configuration
4-27
different types of services, for example, offering different maximum bandwidths. Such
information is all stored on the Radius Server, and the administrator does not need to
configure every switch.
Since the Radius has no standard attribute to represent the maximum data rate, we can only
transfer the authorization information by the manufacturer customized attribute.
The general format of the definition is as follows:
For the maximum data rate, you need to fill in the following values:
The unit of the maximum data rate is kbps.
For users with the maximum data rate of 10M, you need to fill in the following values:
For the customized header, follow those provided above. The maximum data rate is 10M, that
is, 10000kbsp, and makes 0x00002710 in the Hex system. You only need to fill in the
corresponding field.
This function calls for no settings on the device end, and works as long as the device end
supports authorization.