DES-7200 Configuration Guide Chapter 1 File System Configuration
1-13
1.3.8 Copying Files from the
Primary Control Module to
the Secondary Control
Module
The following example shows how to copy firmware_10_4.bin from the primary control module
to the secondary control module:
Check the FLASH space on the secondary control module:
DES-7200#dir slave:/
Directory of slave:/
Mode Link Size MTime Name
-------- ---- --------- -------------------
------------------
1 11014633 2006-01-01 08:00:46 firmware.bin
1 399 2006-01-01 08:01:37 config.text
----------------------------------------------------------
----
2 Files (Total size 11181455 Bytes), 0 Directories.
Total 33030144 bytes (31MB) in this device, 20488192 bytes
(19MB) available.
Copy firmware_10_4.bin from the primary control module to the secondary control module:
DES-7200#copy firmware_10.4.bin slave:/
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! [ok 10,234,345 bytes]
Check the result:
DES-7200#dir slave:/
Directory of slave:/
Mode Link Size MTime Name
-------- ---- --------- -------------------
------------------
1 11014633 2006-01-01 08:00:46 firmware.bin
1 11025788 2008-01-01 08:00:46
firmware_10.4.bin
1 399 2006-01-01 08:01:37 config.text
----------------------------------------------------------
----
3 Files (Total size 11181455 Bytes), 0 Directories.
Total 33030144 bytes (31MB) in this device, 9563693 bytes (9MB)