DES-7200 Configuration Guide Chapter 1 Interface Configuration
1-6
number of slots. The rule of numbering slots is that for panels facing the device,
slots are numbered from front to back, from left to right, and from top down
starting from 1 and increased in turn. Ports in a slot are numbered from left to
right starting from 1 to the number of ports in the slot. For the devices which
have a choice of optical or electrical interfaces, in either case, they use the
same port number. You can view information on a slot and ports on it by using
the show command in CLI.
Aggregate ports are numbered from 1 to the number of aggregate ports
supported on the device.
A SVI is numbered by the VID of its corresponding VLAN.
Cautio
n
The number of the static slot on a device is always 0. However,
dynamic slots (pluggable modules or line cards) are numbered
starting from 1.
1.2.2 Using Interface
Configuration
Commands
Execute the interface command to enter interface configuration mode in the
global configuration mode.
Command Function
DES-7200(config)# interface
interface ID
Input interface to enter the interface
configuration mode in the global configuration
mode. You can also configure an interface
range by using the interface range or
interface range macro command. However,
the interfaces in the same range must be of
the same type and features.
This example shows how to access Gigabitethernet2/1:
DES-7200(config)# interface gigabitethernet 2/1
DES-7200(config-if)#
You can configure the related attributes of the interface in the interface
configuration mode.