DES-7200 Configuration Guide Chapter 8 LCD Configuration
8-5
8.2.3
Configuring Memory Usage
Warning Threshold
System memory is an important resource in system operation. When the available
system memory is insufficient, many important services won't be able to run normally.
The continual drop in system memory may indicate certain faults. Therefore, the
administrator generally expects that the device can give an alarm when system
memory has dropped to a certain extent. The LCD module can give an alarm when the
memory usage is excessively high.
By default, when system memory usage reaches 80%, the warning message will be
operation, transiently high memory usage may be
e frequently (for example, mem ming calculation is running by this
time), which shall be considered normal. Therefore, it is not suggested to set memory
u value usage
w
To e warning thresh g command in
displayed on the LCD, while you can also change this value through configuration.
However, during system
ncountered ory-consu
sage warning threshold to a low in order to avoid frequent memory
arning.
configure memory usag
old (%), execute the followin
global configuration mode:
Command Function
DES-7200# configure terminal
Enter global configuration mode.
DES-7200(config)# memory-rate
Configure memory usage warning
threshold (%)
rising-threshold num
To restore memory usage warning threshold (%) to the default setting, execute "no
figuration mode.
Configuration example:
rning message when memory usage exceeds 60%.
nfigure terminal
DES-7200(config)#
8.3
memory-rate rising-threshold" command in global con
# Configure to display the wa
DES-7200# co
Enter configuration commands, one per line. End with CNTL/Z.
memory-rate rising-threshold 60
LCD Configuration
Instance
Execute the following command to configure LCD display language:
DES-7200(config)# lcd language english //Set display language to
English