DES-7200 Configuration Guide Chapter 3 BFD Configuration
3-31
Min tx interval: 50000 - Min rx interval: 50000
Min Echo interval: 0
Field Description
OurAddr
IP address for the session on the local
end.
NeighAddr IP address for the adjacent session.
LD/RD The session discriminator on the local
and peer end.
RH Whether the peer session responds to
the local session or not.
Holdown(mult) The time of not receiving the Hello
packets on the local end and the
detected timeout time of the session.
State Current session state.
Int The interface number for the session.
Session state is UP and using
echo function with 50 ms interval
Whether the session is in echo mode
and the interval of sending frames.
This information is shown only in the
echo mode.
Local Diag The diagnostic information of the
session.
Demand mode Whether the demand mode is enabled
or not.
Poll bit Whether the session configuration is
modified.
MinTxInt The minimum sending interval of the
session on the local end.
MinRxInt The minimum receiving interval of the
session on the local end.
Multiplier The timeout times detected on the local
end.
Received MinRxInt The minimum sending interval of the
session on the peer end.
Received Multiplier The timeout times detected on the peer
end.
Holdown (hits) Session detection time and the
detected timeout times.